Maintenance — Fuel System

Firewall

  • Top Left: Return to tank

  • Top Right: Vent

  • Bottom: Outlet

Surge Tank

IDQty.DescriptionTool
A1Surge Tankn/a
B101/4”-20 x 1” Socket Head Hex Drive Screw (Stainless Steel)3/16"” Hex Wrench
C21/4” Washer (Stainless Steel)n/a
  • Note that middle and right screws that mount the bottom of the bracket to the 2” x 2” chassis tube mount through the surge tank’s flange.

Check Valve

IDQty.DescriptionTool
A1Check Valven/a
B110-24 x 1-58” Button Head Hex Drive Screw (Stainless Steel)1/8” Hex Wrench
C2#10 Washer (Stainless Steel)n/a

Ethonal Content Sensor

IDQty.DescriptionTool
A11/4”-20 x 3/4” Flanged Button Head Hex Drive Screw (Stainless Steel)5/32” Hex Wrench
B21/4”-20 x 3/4” Flanged Button Head Hex Drive Screw (Stainless Steel)5/32” Hex Wrench
C11/4”-20 Nyloc (Stainless Steel)???

To install:

  • On workbench:

    • Attach sensor to plate with 3/4” screw and nyloc in lower-right corner; ensure that the left sensor and plate holes align and then tighten

    • Place 3/4” screw in left side and 1/2” screw in upper right corner (DO NOT use anything longer than 1/2” because the chassis tube is scalloped on the back side and the screw will bottom out)

  • On chassis:

    • Start the left screw, start the right screw, tighten the two screws



Misc

  • Interior Close-Out Panel: 29x 10-24 x 3/4” Button Head Hex Drive Screw (Stainless Steel)